The transient columns
rise and fall are the one pair that is not settled. The probe drives a
step — silence, a held stimulus, silence again — reads back every frame, and
counts how many it takes for the frame to reach 90 % of its total change each
way (ADR-0039).
That makes ADR-0035’s
{ attack, release } pair visible: a scalar [smoothing] entry selects the same
constant both ways, so its two numbers match; a pair snaps up and glides down, so
fall runs well past rise.
Reading them:
1and1— no easing on whatever the stimulus drives. The frame is fully there the frame after the step.- equal, both large — a scalar
[smoothing]entry, or an asymmetric one whose two constants are close. fallmuch larger thanrise— an{ attack, release }pair doing its job.0and0— the step did not move the frame at all. Check the reactivity columns: this usually means the preset does not respond to the stimulus, not that its easing is instant.
Built from 13c7582 at version 0.158.0. This site tracks main and is not versioned per release.